8. Ship the unit only to the address given at the beginning of this document.

Cleaning Connectors

Caution
Connecting damaged or dirty fibers to the unit can damage the connectors
on the unit.
Never force an optical connector. Some connectors have a ceramic ferrule
that can easily be broken.
Optical cable ends need to be cleaned before using them with the unit.
The following items are required for cleaning:
Filtered compressed air or dusting gas (for example, Tech Spray Envi-Ro-Tech Duster 1671
gas, available from http://www.techspray.com/1671.htm)
Lint-free pipe cleaners (for example, from 3M
Lint-free towels (for example, 10 x10 cm or 4 x 4 in HydroSorb III wipers, available from
http://www.focenter.com/acctech/hydrosobr_wipers.htm)
Optical grade isopropyl alcohol or optical grade 200° ethanol (do not use rubbing alcohol,
which contains 30% water)
To clean the connectors:
1. Blow the sleeve with filtered compressed air (Figure 4).
Figure 4: Connector Cleaning (connector type can vary)
2. Apply optical grade isopropyl alcohol or optical grade ethanol (do not use rubbing alcohol) to
a small area of a lint-free towel and rub the end of the ferrule over the wet area.
3. Wipe the ferrule on a dry area of the lint-free towel.
4. Using the dusting gas or compressed air, blow the end of the ferrule.
5. Apply the alcohol or ethanol to a lint-free pipe cleaner or swab and wipe off the remaining
parts of the connector.
6. With the other end of the pipe cleaner or swab, dry the areas cleaned.