Spares; Replace - JDS Uniphase SKB SERIES User Manual

Fiberoptic switch module
Hide thumbs Also See for SKB SERIES:
Table of Contents

Advertisement

Command packet
OPCODE
Length
0x08
0x02

SPARES?

Description
Query the current number of spare fibers available on the logical switch
specified
Parameters
Switch
Parameter
Switch (unsigned eight-bit)--logical switch
Description
Command packet
OPCODE
Length
0x30
0x01
Response packet
OPCODE
Length
0xB0
0x01

REPLACE

Description
Replace output channel with factory spare
Parameters
Switch, Output, Spare
Parameter
Switch (unsigned eight-bit)--switch number
Description
Output (unsigned eight-bit)--channel number to be replaced
Spare (unsigned eight-bit)--factory spare number
U16 Low_temp
Low_temp (unsigned 16-bit)--Low temperature threshold (233 to 352
°K)
U8 Switch
Switch (unsigned eight-bit)--Logical switch number (1 to 4)
U8 Spares
Spares (unsigned eight-bit)--The number of spare channels
currently configured for the switch
Parameters
Parameters
Parameters
Operating and Maintenance Instructions – 45