Alarm - JDS Uniphase SKB SERIES User Manual

Fiberoptic switch module
Hide thumbs Also See for SKB SERIES:
Table of Contents

Advertisement

ALARM?

Description
Query the alarm register value
Parameters
NA
Parameter
NA
Description
Command packet
OPCODE
Length
0x03
0x00
Response packet
OPCODE
Length
0x83
0x02
Bit
15
Function
EPV
R/W
R
Initial value
0
EPV (EEPROM VERIFY FAIL, bit 15)--This bit indicates that the verify operation of an EEPROM
write failed. It is cleared when the AR is read.
OT (OVER TEMPERATURE, bit 14)--This bit indicates that ambient temperature of the module
has exceeded the high temperature threshold for a period of at least 10 seconds. It is cleared
when the temperature falls below the high temperature threshold.
UT (UNDER TEMPERATURE, bit 13)--This bit indicates that ambient temperature of the module
has dropped below the low temperature threshold for a period of at least 10 seconds. It is cleared
when the temperature falls below the high temperature threshold.
CFO (CONFIGURATION OVERFLOW, bit 12)--This bit indicates that user configuration
commands have been executed more than 50,000 times. This bit is not cleared when the
configuration command counter exceeds 50,000. This bit can only be cleared at the JDS
Uniphase factory.
U16 Alarm_reg
Alarm_reg (unsigned 16-bit)--Current binary value of the Alarm
Register (AR), as indicated in the following table
14
13
12
11
OT
UT
CFO
R
R
R
R
0
0
0
0
Parameters
Parameters
10
9
8
7
6
R
R
R
R
R
0
0
0
0
0
Operating and Maintenance Instructions – 35
5
4
3
2
1
R
R
R
R
R
0
0
0
0
0
0
R
0