Swap_Channel; Latching - JDS Uniphase SKB SERIES User Manual

Fiberoptic switch module
Hide thumbs Also See for SKB SERIES:
Table of Contents

Advertisement

Command packet
OPCODE
Length
0x33
0x3

SWAP_CHANNEL

Description
Swap channel designations between two optical fibers. This command can be
used to reorder channels when the channels have been spliced into the
system incorrectly. The factory-configured order also can be recalled.
Parameters
Switch, Output1, Output2
Parameter
Switch (unsigned eight-bit)--switch number
Description
Output1 (unsigned eight-bit)--first output channel
Output2 (unsigned eight-bit)--second output channel
Command packet
OPCODE
Length
0x34
0x03

LATCHING?

Description
Query latching status of the switch
Parameters
Switch
Parameter
Switch (unsigned eight-bit)--switch number
Description
U8 Switch, U8 Output, U8 Spare
Switch (unsigned eight-bit)--Logical switch number (1 to 4)
Output (unsigned eight-bit)--The replaced output channel (1 to 200)
Spare (unsigned eight-bit)--The factory spare number used for the
replacement (1 to 200)
This command resets the switch.
U8 Switch, U8 Output1, U8 Output2
Switch (unsigned eight-bit)--Logical switch number (1 to 4)
Output1 (unsigned eight-bit)--The first output channel (1 to 200)
Output2 (unsigned eight-bit)--The second output channel (1 to 200)
This command resets the switch.
Parameters
Parameters
Operating and Maintenance Instructions – 46