Hitemp; Lowtemp - JDS Uniphase SKB SERIES User Manual

Fiberoptic switch module
Hide thumbs Also See for SKB SERIES:
Table of Contents

Advertisement

Response packet
OPCODE
Length
0xA3
0x04 to
0x0F
1
The length is variable, depending on the number of switches in the module.

HITEMP

Description
Set the upper temperature threshold
Parameters
Temp
Parameter
Temp (unsigned 16-bit)--The °K high temperature threshold that, if exceeded,
Description
causes the OT alarm register bit to be set
Command packet
OPCODE
Length
0x07
0x02

LOWTEMP

Description
Set the lower temperature threshold
Parameters
Temp
Parameter
Temp (unsigned eight-bit)--The °K low temperature threshold that, if
Description
exceeded, causes the UT alarm register bit to be set
(1-4) * (U8 Sw_Id, U8 Sw_Type, U8 Max_In, U8 Max_Out)
1
Sw_Id (unsigned eight-bit)--Logical switch identification number (1 to
4)
Sw_Type (unsigned eight-bit)--Physical switch type (0:motor or
1:relay)
Max_In (unsigned eight-bit)--Maximum number of inputs of the
switch (1 to 2)
Max_Out (unsigned eight-bit)--Maximum number of outputs of the
switch (1 to 200)
U16 Hi_temp
Hi_temp (unsigned 16-bit)--High temperature threshold (234 to 353
°K)
All temperature information is referenced in degrees Kelvin.
Conversions are as follows:
1 °C = 1 °K and 0 °C = 273 °K approximately
1 °F = 0.55 °K and 0 °F = 255.37 °K
Parameters
Parameters
Operating and Maintenance Instructions – 44