INSTALLING THE HEAT SHIELD

1 . Bend the tabs on the heat shield to provide a 1/2" dead air space between exhaust
2 . Attach the heat shield to the exhaust pipe using the clamps (Fig . 30) . Bend the heat
3 . For vehicles with the large resonator on the rear exhaust, in order for the heat shield
4 . Once the tabs are bent correctly, attach the heat shield to the resonator or exhaust
MN-970
pipe and heat shield (Fig . 29) .
shield for maximum clearance to the air spring .
Distance from
heat shield to
bellows must
be at least 1/2"
to be clamped onto the resonator, it will be necessary to double up on the clamps so
they can go around it (Fig . 31) .
pipe as shown in Figure 32 .
Bend tabs up
At least 1/2" of
dead air space
"
1/2
fig. 30
fig. 29
fig. 31
fig. 32
15