MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
Sides
Floor
Back (Single Sided)
Back (See-Thru)
Front
Clearance around vent pipe
The image above shows a typical installation.
All framing, finishing, and construction materials that fall within 4" (102mm) of either the sides or top of
the fireplace must be non-combustible and ½" below the unit.
Any materials that cover the front face or rear face of the fireplace must be non-combustible. Allow
clearance for removal of fireplace trim, screen, and glass.
The fireplace must be secured to the framing studs using the nailing flanges as shown above. Use 2
screws or nails per nailing flange to secure the fireplace.
The sheet metal face of this fireplace must be covered by a non-combustible material, it may not be left
exposed.
The floor the fireplace immediately rests on must be constructed of non-combustible material with an R
factor of at least .37, with a minimum thickness of ½" (13mm).

CLEARANCES

GEMINI/CELESTE 48
4" (102mm)
1/2" (13mm)
2" (51mm)
12" (305mm)
12" (305mm)
1.5" (38mm)
CELESTE/GEMINI 48/60/72
Models 8930/8935/8940/8945/8950/8955
GEMINI/CELESTE 60
4" (102mm)
1/2" (13mm)
2" (51mm)
12" (305mm)
12" (305mm)
1.5" (38mm)
GEMINI/CELESTE 72
4" (102mm)
1/2" (13mm)
2" (51mm)
12" (305mm)
12" (305mm)
1.5" (38mm)