How to Confirm Charging Current
It is very important to know the maximum charging current of the battery as excessive
current could influence the life span of battery and/or cause damages. In addition, excessive
current can cause heating and/or explosion of the battery during the charging process.
The charging and discharging capacity of battery is usually marked with C value. Multiplying
the charging C value and battery capacity equals to the maximum charging current support-
ed by the battery. For example, for a 1000 mAh battery with a charging capacity of 5C, the
maximum charging current would be 1000*5=5000mA; therefore, the maximum charging
current is 5A.
For a lithium battery, if it is impossible to confirm the supported charging C value, please set
the charging current below 1C for the sake of its (lithium battery) safety.
The reference relation between C value and charging time: charging time ≥60 minutes/
charging C value (it therefore needs around 60~70 minutes to complete charging with 1C).
Due to differences in battery conversion efficiency, the period to complete the charging