Set Id For This Product - Patlite PHC-D08 User Manual

Interface converter
Table of Contents

Advertisement

3.3.3.
<Set ID for this product>
Sending data in the following form will change the ID of this product. Two ASCII bytes are designated in the data
section to change to a new ID. The configuration range for each byte of data in the data section can set up from 0
[30H] to ? [3FH].
[Transmission Example]
In this example,
• Send Data
Header
@
[40H]
• Reply data
Normal response
Data
ACK
[06H]
Response Error
Data
NAK
[15H]
The following are conditions which will get a NAK reply and the error contents.
Transmission Condition
Command error
Data error
Data size error
Timeout
* Do not transmit the following command, before this product transmits reply data. It may not operate
normally.
the ID set at 56 [35H 36H] shall be changed to 21 [32H 31H].
ID
5
6
[35H]
[36H]
When a command other than on the list of commands is specified
When data, other than 0[30H] - ?[3FH], is used
When the number of bytes in the send data is different
Reply interval between data is more than 5 seconds after receipt of header
Command
Data
?
2
[3FH]
[32H]
Error Contents
End Code
1
!
[31H]
[21H]
3
19