2.2.2.
The Power Supply Output Terminal can be used to control an external load when an AC Adaptor is used. When
using the Power Supply Output Terminal, wire in accordance to the directions indicated below.
[Wiring Method]
1.
Use a minus driver to push in the tab of the control unit's terminal buss slot.
2.
Insert a lead wire into the slot. (Keep pushing the tab while inserting)
3.
Release the minus driver to lock the lead wire in place.
2
Applicable Wires
Wire Coating
Strip Length
Suitable Actuator Tool
Caution
MEMO
10
Power Supply Output Terminal Wiring
Single Wire: Diameter 0.4 mm to 1.2 mm (AWG26 to AWG18)
Stranded Wire: Diameter 0.2 mm
* Single wire diameter shall be 0.18 mm or more for stranded wire.
• Do not connect any voltage to the Power Supply Output Terminal. Failure to comply will
result in damage to the product and possible fire.
• Maintain the consumption current of the equipment linked to the Power Supply Output
Terminal so as to not exceed the ratings indicated below. Do not connect any equipment
which consumes more current than the rated capacity. Failure to comply may result in
malfunction or damage.
• The Power Supply Output Terminal cannot be used without an AC Adaptor used. Be sure to
connect an AC Adaptor when using the Power Supply Output Terminal.
+ -
2
to 1.25 mm
9mm
Width of flathead screwdriver bit: 1.5 to 2.5 mm
Thickness of bit: 0.5 to 0.7 mm
Power Output Voltage
Power Output Current
500mA or less
2
(AWG24 to AWG16)
DC24V