Turn Off Specified Output Terminal - Patlite PHC-D08 User Manual

Interface converter
Table of Contents

Advertisement

3.3.2.
Sending data in the following format will control the specified Output Terminal to turn "OFF." The bit in the data
section specified as 0, will maintain the specified Output Terminal's condition, and the bit in the data section
specified as 1 will turn off the specified Output Terminal.
[Transmission Example]
In this example, the Output Terminals 1, 5, and 7 are turned OFF.
• Send Data
Header
[40H]
3
• Reply Data
Normal Response
Data
ACK
[06H]
Response Error
Data
NAK
[15H]
The following are conditions which will get a NAK reply and the error contents.
Transmission Condition
Command error
Data size error
* Do not transmit the following command, before this product transmits reply data. It may not operate
normally.
18
<Turn OFF Specified Output Terminals>
ID
@
?
[3FH]
[3FH]
15 14 13 12 11 10 9
0 0 1 1 0 1 0 1 0 0 1 1 0 0 0 1
When a command other than on the list of commands is specified
Data error
Timeout
Reply interval between data is more than 5 seconds after receipt of header
Command
?
0
[30H]
8
7
Error Contents
When data, other than 0[30H] - ?[3FH], is used
When the number of bytes in the send data is different
Data
5
1
[35H]
[31H]
6
5
4
3
2
1
0
Output Terminal 1
Output Terminal 2
Output Terminal 3
Output Terminal 4
Output Terminal 5
Output Terminal 6
Output Terminal 7
Output Terminal 8
End Code
!
[21H]

Advertisement

Table of Contents
loading

Related Products for Patlite PHC-D08

This manual is also suitable for:

Phc-d08n

Table of Contents