Kusam-meco KM 078 Instructions Manual

Kusam-meco KM 078 Instructions Manual

Ac+dc true rms digital clampmeter with vfd, ef-detection, amptip function for low current measurement

Advertisement

Quick Links

An ISO 9001:2008 Company
SPECIAL FEATURES :
TM
AmpTip low-current range calibrated at
Jaw-tip for slim-conditions for accurate readings
MAX/MIN/AVG Recording mode (Auto ranging)
VFD-V & Hz for fundamental V/Hz of most
Variable-Frequency-Drives.
Display Hold & Non-Contact EF-Detection (NCV)
GENERAL SPECIFICATIONS :
Sensing : AC+DC;
True RMS
Jaws Opening size : 35mm Max.
Display : 3-5/6 digits 6000 counts
Update Rate : 5 per second nominal
Polarity : Automatic
Operating Temperature :
0ºC to 40ºC
Relative Humidity :
Maximum relative humidity
80% for temperature up to 31ºC decreasing
linearly to 50% relative humidity at 40ºC
Altitude : Operating below 2000m
Storage Temperature : -20°C ~ 60°C, \
<80% R.H. (with battery removed)
SAFETY :
Safety :
Double insulation per UL/IEC/EN61010-1
Ed. 3, IEC/EN61010-2-033 Ed.1,CAN/CSA C22.2
No.61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 3 &
IEC/EN61010-031 Ed. 1.1
Measurement Category :
CAT III 600V AND
CAT IV 300V AC & DC
Overload Protection :
Current & Hz functions via jaws : 600ADC/AC rms
at <400Hz.
Voltage : 660VDC rms
Other functions via terminals : 600VDC/ VAC rms
Pollution Degree : 2
ACCESSORIES : Test leads set, Users Manual, Carrying case.
Accuracy is ± (% of reading digits + number of digits) or otherwise specified, at 23 C ± 5 C
Maximum Crest Factor <2.5:1 at full scale & <5:1 at half scale or otherwise specified, and with frequency spectrum not exceeding
REGULAR CLAMP-ON AC CURRENT
Range
Resolution
50Hz ~ 100Hz
3)
60.00 A
0.01
0.1
600.0 A
100Hz ~ 400Hz
3)
0.01
60.00 A
0.1
600.0 A
1)
Induced error from adjacent current-carrying conductor : < 0.01A/A
2)
Maximum Crest Factor <2:1 at full scale & <4:1 at half scale.
3)
Add 10d to the specified accuracy @ < 9A.
®
An ISO 9001:2008 Company
Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2013-2014/KM 076.cdr
AC+DC TRUE RMS DIGITAL CLAMPMETER WITH
®
VFD, EF-DETECTION, AMPTIP FUNCTION FOR
Back-lighted easy-to-read LCD display
Fast 80ms Peak-RMS mode to capture
in-rush currents
Auto-ranging
mode on DCA, DC+ACA ranges
Temperature Coefficient : Nominal 0.15 x
(specified accuracy) / C @ (0 C –– 18 C or 28 C –– 40 C),
or otherwise specified
Power Supply : Standard 1.5V AAA Size Battery X 2
Power Consumption : typical 13mA
Low Battery :
APO timing : Idle for 32 minutes
APO Consumption : typical 5 A
Dimension : 223(L) x 76(W) x 37(H)mm
Weight : approx 234 gms.
E.M.C. :
EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) :
DCA and DC+ACA Functions, in an RF field of 1V/m :
Total Accuracy = Specified Accuracy + 20 digits at around 405MHz
Ohm Functions, in an RF field of 1V/m :
Other Functions, in an RF field of 3V/m :
Transient Protection : 6.0kV (1.2/50 s surge)
Rugged Fire retarded casing.
LVD EN61010-2-032/EN61010-2-032/EN61010-2-033 to CAT III 600V & CAT IV 300V
ELECTRICAL SPECIFICATIONS : KM 078
the specified frequency bandwidth for non-sinusoidal waveforms.
1) 2)
Accuracy
A
±(1.8%rdg + 5dgts)
A
A
±(2.0%rdg + 5dgts)
A
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022-24156638,
Email : kusam_meco@vsnl.net,
LOW CURRENT MEASUREMENT
Relative mode with DC-Zero
o
o
o
Below approx. 2.85V for Capacitance & Hz
Below approx. 2.5V for other functions
Meets EN61326-1 : 2006 (EN55022, EN61000-3-2,
Total Accuracy = Specified Accuracy + 25 digits
Total Accuracy = Specified Accuracy + 20 digits
REGULAR CLAMP-ON DC CURRENT
Range
3)
60.00 A
600.0 A
1)
Induced error from adjacent current-carrying conductor : < 0.01A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual
readings, if any
3)
Add 10d to the specified accuracy @ < 9A
All Specifications are subject to change without prior notice
Tel. : 022-24124540, 24181649,
MODEL KM 078
o
o
Preliminary Data
o
o
Accuracy
Resolution
0.01
A
±(2.0%rdg + 5dgts)
0.1
A
Fax : 022-24149659
Website : www.kusamelectrical.com
1) 2)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM 078 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kusam-meco KM 078

  • Page 1 LVD EN61010-2-032/EN61010-2-032/EN61010-2-033 to CAT III 600V & CAT IV 300V ACCESSORIES : Test leads set, Users Manual, Carrying case. ELECTRICAL SPECIFICATIONS : KM 078 Accuracy is ± (% of reading digits + number of digits) or otherwise specified, at 23 C ± 5 C Maximum Crest Factor <2.5:1 at full scale &...
  • Page 2 REGULAR CLAMP-ON DC+AC CURRENT AMPTIP CLAMP-ON AC CURRENT 1) 2) 1) 2) 3) Range Accuracy Range Accuracy Resolution Resolution 50Hz ~ 60Hz DC, 50Hz ~ 100Hz ±(1.5%rdg + 5dgts) 0.01 A 0.01 60.00 A 60.00 A ±(2.2%rdg + 7dgts) Induced error from adjacent current-carrying conductor : < 0.01A/A 600.0 A Specified with DC-Zero mode applied to offset the non-zero residual 100Hz ~ 400Hz...
  • Page 3 ® USE TRUE RMS WHEN MEASURING AC WAVEFORMS The waveforms on today’s AC power lines are anything but clean. Electronic equipment such as office computers, with their switching power supplies, produce harmonics that distort power-line waveforms. These distortions make measuring AC voltage inaccurate when you use an averaging DMM.
  • Page 4: List Of Products

    Digital Non-contact (infrared) Thermometer Maximum Demand Controller/Digital Power Meter Digital Hand Held Temperature Indicators ® MODEL - KM 078 G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel. : (022) 24124540, 24181649. Fax : (022) 24149659 Email : kusam_meco@vsnl.net...
  • Page 5 If the instrument is used in manner not specified by the manufacturer, the protection provided MODEL - KM 078 by the instrument may be impaired. The meter protection rating, against the users, is double insulation per UL/IEC/EN61010-1 Ed.
  • Page 6: Special Features

    ® ® WARNING : II. INTERNATIONAL ELECTRICAL SYMBOLS : To reduce the risk of fire or electric shock, do not expose this product Caution ! Refer to the explanation in this Manual. to rain or moisture. The meter is intended only for indoor use. To avoid electrical shock hazard, observe the proper safety Caution ! Risk of electric shock.
  • Page 7: Specifications : General Specifications

    ® ® V. SPECIFICATIONS : SAFETY : GENERAL SPECIFICATIONS : Safety : Double insulation per UL/IEC/EN61010 Display : 3-5/6 digits 6000 counts -1 Ed. 3, IEC/EN61010-2-033 Ed. 1, Polarity : Automatic CAN/CSA C22.2 No. 61010-1 Ed. 3, Jaw opening & Conductor diameter : 35mm max IEC/EN61010-2-032 Ed.
  • Page 8 ® ® Regular Clamp-on DC Current : ELECTRICAL SPECIFICATIONS : Accuracy is ± (% of reading digits + number of digits) or otherwise specified @ Range Accuracy 1) 2) Resolution 23ºC ± 5ºC. Maximum Crest Factor < 2.5:1 at full scale & < 5:1 at half scale or 60.00 A 10 mA ±(2.0%rdg + 5dgts)
  • Page 9 ® ® AC Voltage (with Digital Low-pass Filter) : Hz Line Level Frequency : Sensitivity Range Accuracy Resolution Range Function (Sine RMS) 50Hz ~ 60Hz 50 V 5.00Hz~999.9Hz 600 V ±(1.0%rdg + 5dgts) 600.0 V A (AmpTip ) 20 A 50.00Hz~400.0Hz Input Impedance : 10M , 100pF nominal 20 A...
  • Page 10: Product Description

    ® ® VI. PRODUCT DESCRIPTION : VII. OPERATION : WARNING : Before and after hazardous voltage measurements, This manual uses only representative model(s) for illustrations. test the voltage function on a known source such as line voltage to Please refer specification details for function availability to this model. determine proper meter functioning.
  • Page 11 ® ® Electric Field EF-Detection CAUTION & WARNING for Non-Invasive (Clamp-on) The meter displays “EF” when it is ready. Signal strength is indicated Current Measurements : as a series of bar-graph segments on the display together with variable beep tones. CAUTION : (Application and Removal of the Clamp-on Jaws) For non-invasive current measurements, press the jaw trigger and clamp the jaws...
  • Page 12 ® ® Non-Invasive AmpTip Low-Current Functions : Non-Invasive Regular Current Functions : ACA, DCA, DC+ACA & Hz : ACA, DCA, DC+ACA & Hz : Input is made via the clamp jaws with best accuracy specified near Input is made via the clamp jaws with best accuracy specified at the the jaw tip area for small conductors low-current measurements.
  • Page 13 ® ® Resistance, Continuity & Diode functions : Capacitance functions : Inputs are made through the test lead terminals COM/+. Defaults at Inputs are made through the test lead terminals COM/+. Capacitance. Defaults at Resistance. Press SELECT button momentarily to select the subject functions in sequence.
  • Page 14 ® ® Using the Complementary Beeper feature : Relative-Zero ( ) mode : Relative-Zero allows the user to offset the meter consecutive The Complementary Beeper feature is selected in Power-up option. measurement with the main display displaying reading as the Press and hold the REC button while turning the meter on to enable.
  • Page 15: Maintenance : Warning

    ® ® Intelligent Auto-Power-Off (APO) : Cleaning and Storage : The Auto-Power-Off (APO) mode turn the meter off automatically to Periodically wipe the case with a damp cloth and mild detergent; do extend battery life after approximately 32 minutes of no specified not use abrasives or solvents.
  • Page 16: Test Certificate

    ® WARRANTY MUMBAI Each “KUSAM-MECO” product is warranted to be free from defects in TEST CERTIFICATE material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods.

Table of Contents