SPECIAL FEATURES :
TM
AmpTip low-current range calibrated at Jaw-tip for slim-conditions for accurate readings
MAX/MIN/AVG Recording mode (Auto ranging)
VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives
Display Hold & Non-Contact EF-Detection (NCV)
Probe-Contact EF-Detection.
GENERAL SPECIFICATIONS :
í Sensing : AC;
True RMS
í
Jaws Opening size & conductor diameter : 30mm Max.
í
Display : 3-5/6 digits 6000 counts
í
Update Rate : 5 per second nominal
í
Polarity : Automatic
í
Operating Temperature :
0ºC to 40ºC
í
Relative Humidity :
Maximum relative humidity 80% for temperature up to 31ºC
decreasing linearly to 50% relative humidity at 40ºC
í
Altitude : Operating below 2000m
í
Storage Temperature : -20°C ~ 60°C, <80% R.H. (with battery removed)
í
Temperature Coefficient : Nominal 0.15 x (specified accuracy) / C @ (0 C –– 18 C or 28 C –– 40 C),
or otherwise specified
í
Power Supply : Standard 1.5V AAA Size Battery X 2
í
Power Consumption : typical 4.3mA
í
Low Battery :
Below approx. 2.85V for Capacitance & Hz
Below approx. 2.5V for other functions
í
APO timing : Idle for 32 minutes
í
APO Consumption : typical 5mA
í
Dimension : 217(L) x 76(W) x 37(H)mm
í
Weight : approx 186 gms.
SAFETY :
Safety :
Double insulation per UL/IEC/EN61010-1 Ed. 3, IEC/EN61010-2-033 Ed. 1, CAN/CSA C22.2
No. 61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 3 & IEC/EN61010-031 Ed. 1.1
Measurement Category :
CAT III 600V AND CAT IV 300V AC & DC
E.M.C. :
Meets EN61326-1 : 2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) :
DCA and DC+ACA Functions, in an RF field of 1V/m :
Total Accuracy = Specified Accuracy + 20 digits at around 405MHz
DCmA and Ohm Functions, in an RF field of 1V/m : Total Accuracy = Specified Accuracy + 25 digits
Other Functions, in an RF field of 3V/m : Total Accuracy = Specified Accuracy + 20 digits
Overload Protection :
Current & Hz functions via jaws : 600ADC/AAC rms at <400Hz
Voltage & 3-Phase Rotation functions via terminals : 660VDC/ 920VAC rms
Other functions via terminals : 600VDC/ VAC rms
Pollution Degree : 2
Transient Protection : 6.0kV (1.2/50ms surge)
Rugged Fire retarded casing.
LVD EN61010-1/61010-2-032/EN61010-2-033 to CAT III 600V & CAT IV 300V
ACCESSORIES :
Test leads set, Users Manual, Battery & Carrying Case.
®
An ISO 9001:2008 Company
Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2015 new arrival catalogs/KM 072.cdr
600A AC TRUE RMS DIGITAL CLAMPMETER WITH
®
VFD, EF-DETECTION, AMPTIP FUNCTION FOR
o
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022-24156638,
Email : kusam_meco@vsnl.net,
LOW CURRENT MEASUREMENT
o
o
o
o
All Specifications are subject to change without prior notice
Tel. : 022-24124540, 24181649,
MODEL KM 072
Preliminary Data
Fax : 022-24149659
Website : www.kusamelectrical.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the KM 072 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kusam-meco KM 072

  • Page 1 G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct.: 022-24156638, Tel. : 022-24124540, 24181649, Fax : 022-24149659 Email : kusam_meco@vsnl.net, Website : www.kusamelectrical.com An ISO 9001:2008 Company Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2015 new arrival catalogs/KM 072.cdr...
  • Page 2 Test Current : 0.3mA typically Accuracy : ±(1%rdg + 5dgts) Open Circuit Voltage : < 3.5VDC typically DC-bias, if any, not more than 50% of Sine RMS All Specifications are subject to change without prior notice Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2015 new arrival catalogs/KM 072.cdr...
  • Page 3 ¬ Digital Non-contact (infrared) Thermometer ¬ Maximum Demand Controller/Digital Power Meter ¬ Digital Hand Held Temperature Indicators ® MODEL - KM 072 G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel.
  • Page 4 If the instrument is used in manner not specified by the manufacturer, the protection provided MODEL - KM 072 by the instrument may be impaired. The meter protection rating, against the users, is double insulation per UL/IEC/EN61010-1 Ed.
  • Page 5 ® ® WARNING : II. INTERNATIONAL ELECTRICAL SYMBOLS : To reduce the risk of fire or electric shock, do not expose this product Caution ! Refer to the explanation in this Manual. to rain or moisture. The meter is intended only for indoor use. To avoid electrical shock hazard, observe the proper safety Caution ! Risk of electric shock.
  • Page 6 ® ® V. SPECIFICATIONS : SAFETY : GENERAL SPECIFICATIONS : Safety : Double insulation per UL/IEC/EN61010 Display : 3-5/6 digits 6000 counts -1 Ed. 3, IEC/EN61010-2-033 Ed. 1, Polarity : Automatic CAN/CSA C22.2 No. 61010-1 Ed. 3, Jaw opening & Conductor diameter : 30mm max IEC/EN61010-2-032 Ed.
  • Page 7 ® ® AC Voltage (with Digital Low-pass Filter) : ELECTRICAL SPECIFICATIONS : Accuracy is ± (% of reading digits + number of digits) or otherwise specified @ Range Accuracy Resolution 23ºC ± 5ºC. Maximum Crest Factor < 2.5:1 at full scale & < 5:1 at half scale or 50Hz ~ 60Hz otherwise specified, and with frequency spectrum not exceeding the specified ±(1.0%rdg + 5dgts)
  • Page 8 ® ® Hz Line Level Frequency : VI. PRODUCT DESCRIPTION : Sensitivity Range Function This manual uses only representative model(s) for illustrations. (Sine RMS) Please refer specification details for function availability to this model. 50 V 5.00Hz~999.9Hz 600 V 1. Antenna area for Non-Contact EF- A (AmpTip ) 20 A 50.00Hz~400.0Hz...
  • Page 9 ® ® VII. OPERATION : CAUTION & WARNING for Non-Invasive (Clamp-on) WARNING : Before and after hazardous voltage measurements, Current Measurements : test the voltage function on a known source such as line voltage to determine proper meter functioning. CAUTION : ACV, DCV, Line-level Hz &...
  • Page 10 ® ® Electric Field EF-Detection Non-Invasive AmpTip Low-Current Functions : The meter displays “EF” when it is ready. Signal strength is indicated ACA & Hz as a series of bar-graph segments on the display together with Input is made via the clamp variable beep tones.
  • Page 11 ® ® W Resistance, Continuity & Diode functions : USING THE COMPLEMENTARY BEEPER FEATURE : Inputs are made through the test lead terminals COM/+. Defaults at W Resistance. Press SELECT button momentarily to The Complementary Beeper feature is selected in Power-up option. select the subject functions in sequence.
  • Page 12 ® ® Intelligent Auto-Power-Off (APO) : Cleaning and Storage : The Auto-Power-Off (APO) mode turn the meter off automatically to Periodically wipe the case with a damp cloth and mild detergent; do extend battery life after approximately 32 minutes of no specified not use abrasives or solvents.
  • Page 13 ® WARRANTY MUMBAI Each “KUSAM-MECO” product is warranted to be free from defects in TEST CERTIFICATE material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods.