Kusam-meco KM 039F Operation Manual

Digital trms fork clampmeter

Advertisement

Quick Links

LIST OF PRODUCTS
¬ Digital Multimeter
¬ Digital AC & AC/DC Clampmeter
¬ AC Clamp Adaptor
¬ AC/DC Current Adaptor
¬ Thermo Anemometer
¬ Thermo Hygrometer
¬ Distance Meter
¬ Digital Lux Meter
¬ Network Cable Tester
¬ Power Factor Regulator
¬ Earth Resistance Tester
¬ Digital Panel Meters
¬ DC Power Supplies
¬ High Voltage Detector
¬ Calibrators
¬ Gas Analysers
¬ Frequency Counter
¬ Function Generator
¬ Phasing Sticks
¬ Battery Tester
¬ Waterproof Pen Testers
¬ Solar Power Meter
¬ EMF Detector
¬ Wood, Paper & Grain Moisture Meter
¬ Transistorised Electronic Analog & Digital Insulation
Resistance Testers(upto 10 KV)
¬ Digital Sound Level Meter & Sound Level Calibrator
¬ Digital contact & Non-contact Type Tachometer
¬ Digital Non-contact (infrared) Thermometer
¬ Maximum Demand Controller/Digital Power Meter
¬ Digital Hand Held Temperature Indicators
OFFICE ADDRESS
Shop no.18, 1st Floor, CIDCO Shopping
G 17, Bharat Industrial Estate, T. J. Road,
Complex, Plot # 9, Sector-7,
Sewree (W), Mumbai - 400 015. INDIA.
Rajiv Gandhi Marg, Sanpada,
Sales Direct : (022) 24156638
Navi Mumbai - 400705.
Sales Direct :(022) 27754546
Tel. : 24124540, 24181649
Tel. :27750662, 27750292
Email : sales@kusam-meco.co.in
Email : sales@kusam-meco.co.in
Website : www.kusamelectrical.com
Website : www.kusamelectrical.com
®
SERVICE CENTER
AN ISO 9001:2015 COMPANY
DIGITAL TRMS FORK
CLAMPMETER
MODEL - KM 039F
OPERATION MANUAL
® ®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM 039F and is the answer not in the manual?

Questions and answers

Summary of Contents for Kusam-meco KM 039F

  • Page 1 ¬ Battery Tester ¬ Waterproof Pen Testers ¬ Solar Power Meter ¬ EMF Detector MODEL - KM 039F ¬ Wood, Paper & Grain Moisture Meter ¬ Transistorised Electronic Analog & Digital Insulation Resistance Testers(upto 10 KV) ¬ Digital Sound Level Meter & Sound Level Calibrator ¬...
  • Page 2: Table Of Contents

    ® ® TABLE OF CONTENTS DIGITAL TRMS FORK CLAMPMETER TITLE PAGE NO. MODEL - KM 039F Safety............Cenelec Directives........III. Special Features......... IV. General Specifications....... Electrical Specifications......VI. Product Description ........VII. Maintenance..........VIII . Test Certificate........... Warranty............26...
  • Page 3: Safety

    ® ® Keep your hands / fingers behind the hand / finger barriers (of the meter and the test probe assembly, where applicable) that indicate I. SAFETY : the limits of safe access of the hand held parts during measurements. The meter meets IEC/EN/CSA_C22.2_No./UL standards of 61010-1 Inspect lead wires, connectors, and probes for damaged insulation Ed.
  • Page 4: Cenelec Directives

    ® ® BRIEF INFORMATION ON MEASUREMENT CATEGORIES SPECIAL FEATURES : Measurement Category IV is applicable to test and measuring ●Fork-clamp Current measurement circuits connected at the source of the building- ’ s l o w voltage ●12mm Slim-Probe open jaws for easy slide into tight wirings. MAINS installation Examples a r e measurements on devices installed before the main fuse or circuit bre a k e r in the building ●...
  • Page 5: General Specifications

    ® ® SPECIFICATIONS: ● Overload Protections: GENERAL SPECIFICATIONS: ● Basic Accuracy : 1.0% Current via Fork-clamp: 200Aac rms at <400Hz ● Sensing : True RMS Voltage via terminals: 660Vdc / 920Vac rms ● Display : 3-5/6 digits 6000 counts LCD display Other functions via terminals: 600Vdc/Vac rms ●...
  • Page 6: Electrical Specifications

    ® ® Electrical Specifications: Accuracy is ± (% reading digits + number of digits) o r otherwise Hz (LPF added) Line-Level Frequency specified, at 23 °C ± 5°C. Maximum Crest Factor < 2 : 1 at full Sensitivity Range Function scale &...
  • Page 7 ® ® TEMPERATURE BEEPLIT DIODE TESTER Range Accuracy -40.0ºC ~ 99.9ºC Range Accuracy Resolution 1.0% ~ 1ºC 100.0ºC ~ 400ºC ±(1.5%rdg + 5dgts) 3.000 V 0.001 V -40.0ºF ~ 211.8ºF Test Current : 0.3mA typically 1.0% ~ 2ºF 212ºF ~ 752ºF Open Circuit Voltage : <...
  • Page 8: Product Description

    ® ® 3) PRODUCT DESCRIPTION 4) OPERATION This user's manual uses only representative model(s) for illustrations. WARNING Please refer detailed specifications for function availability to each Before and after hazardous voltage measureme n ts, test the model. 1) Fork-clamp for ACA magnetic voltage function on a known source such as line voltage to field pick up determine proper meter functioning...
  • Page 9 ® ® Fork-clamp ACA Note: ACV and Line-level Hz functions are bundled with LPF low- Input is made via the Fork-clamp where best accuracy is spec i fi ed pass filter, and are capable of dealing with most VFD (Variable at the center indicator area.
  • Page 10 ® ® diode. The digital displ ay shows over - range If the diode is good. Any o ther readings indicate the diode is resistive or shorted (defective). ●Beep-Alert & BeepLit indication: When the display reading drops across 0.850V, the meter alerts a short bee p sound to signal a reasonable forward voltage drop o f common diodes.
  • Page 11 ® ® ●Probe-Contact EF -Detection (Single-pole): DCmA For more precise indication of liv e wires, such as distinguishing Inputs are made via the test lead terminals COM/+. between Live and Ground connections, use one single test probe ●Application notes: to test via terminal COM for direct metal contact probing to achieve The DC A function is designed especially the most distinctive indications.
  • Page 12 ® ® ● Insufficient ground (must be at least 4 times the detector area) CAUTION Discharge capacito r (s) before making capacitance measurements. ● Flame lifting off burner head (ground), or not continuously in Large valu e capacitors should be discharged through an contac t with the flame rod appropr i a t e resistance load .
  • Page 13 ® ® In other words, the meter will intelligently reset the APO mode when RECORD mode Press the REC button momentarily to activate MAX/MIN recording it is under normal measurements. To wake up the meter fr o m APO mode. LCD MAX & MIN turn on. The meter beeps when new MAX , press the SELECT button momentarily and release, or turn the (maximum) or MIN (minimum) reading is updated.
  • Page 14: Maintenance

    ® ® 5) MAINTENANCE Battery replacement WARNING The meter uses standard 1.5V AAA Size (IEC R03) battery X 2 To avoid electrical shock, disconnect the meter from any circuit, Loosen the 2 captive screws from the bottom case. Lift the bottom case.
  • Page 15: Test Certificate

    MUMBAI WARRANTY TEST CERTIFICATE Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of DIGITALTRMS FORK CLAMPMETER goods.

Table of Contents