3.4

TechNIcAl DATA

gasoline engine, power
fuel capacity
max. operating pressure
max. volume flow
volume flow at 0.6 mpa (6 bar) with water
max. temperature of the coating material
material hose connection
max. viscosity
max. size of tip with a spray gun
empty weight
Dimensions (l x W x h)
hydraulic oil filling quantity
Hydraulics housing
Gears
max. vibration at the spray gun
max. sound pressure level
* Place of measurement: 1 m distance from unit and
1.60m above floor, 12 MPa (120 bar) operating pressure,
reverberant floor
120cc (Honda)
0.66 US gal (2.5 l)
3300 PSI (22,8 MPa, 228 bar)
0.75 gal/min (2.8 l/min)
0.61 gal/min (2.3 l/min)
109º F (43 °C)
1/4"-18 NPSM
20,000 mPas
0.027" – 0.68 mm
192 lbs (87 kg)
65" x 32.5" x 39.5"
(165 cm x 82.5 cm x 100.3 cm)
1.15 liter
0.05 liter
lower than 2.5 m/s²
74 dB (A)*
operATINg TemperATure
This equipment will operate correctly in its intended ambient,
at a minimum between +50ºF (10°C) and 104ºF (+40°C).
relATIve humIDITy
The equipment will operate correctly within an environment
at 50% RH, 104ºF (+40°C). Higher RH may be allowed at lower
temperatures.
Measures shall be taken by the Purchaser to avoid the harmful
effects of occasional condensation.
AlTITuDe
This equipment will operate correctly up to 2100 m (6890 ft)
above mean sea level.
Honda service center can add a high-altitude kit
i
if operation at higher elevation is required.
TrANSporTATIoN AND STorAge
This equipment will withstand, or has been protected against,
transportation and storage temperatures of -13ºF (-25°C) to
131ºF (55°C) and for short periods up to 150ºF (70°C).
It has been packaged to prevent damage from the effects of
normal humidity, vibration and shock.