cabinet temperature, or higher ambient temperature and less insulation will
cause the capacity to reduce and may not maintain a temperature of 55
• In order for the unit to operate properly, the ambient temperatures for WM-
1500HTD should not be higher than 78
• In order for the unit to operate properly, the ambient temperatures for WM-
2500HTD should not be higher than 95
• Mounting brackets, screws, gaskets and other sealing materials are not
included.
• Do not install any ducts onto the supply, return, intake or exhaust.
• Because of potential safety hazards that may occur under certain conditions,
we strongly recommend against the use of an extension cord. However, if you
still elect to use an extension cord, it is absolutely necessary that it be a UL
LISTED 3-wire grounding type appliance extension cord. The cord should
have a 3-blade grounding plug, and a 3-slot receptacle that will plug into the
appliance. The marked rating of the extension cord should be 115 V, 15 A.
1. Cabinet Location
• Place the wine cabinet in a properly ventilated location. Otherwise, heat
exhaust from the cooling unit will build up, and the unit will not operate
properly.
• The exhaust area must not be in an enclosed space, and must be in an area
with ventilation. The ambient temperatures should not be higher than 78°F or
lower than 50°F for a WM-1500HTD unit. The ambient temperatures for a
WM-2500HTD unit should not be higher than 95°F or lower than 50°F.
1) Rear Exhaust Location
• Leave min 6" clearance from the rear to the wall.
• Leave min 12" clearance from the top to the ceiling.
• Leave min 6" clearance from the left and right sides.
2) Front Exhaust Location
• Leave min 6" clearance from the front, if the left and right sides are
unobstructed.
• Or, leave min 36" clearance from the front, if the left and right sides
obstructed.
3) Top Exhaust Location
• Leave min 12" from the top to the ceiling.
• Leave min 2" clearance from the rear to the wall.
• Leave min 2" clearance from the left and right sides.
4) Side Exhaust Location
• Leave min 6" clearance from the left or right side to the wall.
• Leave min 12" clearance from the top to the ceiling.
°
F or lower than 50
°