Furuno FCV-2100 Installation Manual page 27

Fish size indicator
Hide thumbs Also See for FCV-2100:
Table of Contents

Advertisement

2.2.5
External KP control
To control the external KP, connect the external fish finder with a MPYCSLA-4 or
equivalent cable (local supply). Refer to the interconnection diagram at end of this
manual to connect the cable.
1. Fabricate the cable ends referring to the figure below.
2. Open the cover of the transceiver unit.
WAGO connector
WAGO connector
EXT-KP port
3. Detach the WAGO connector (TB2) from the board.
4. Unfasten the seal nut of EXT-KP port and disassemble the seal assembly.
Remove a seal grommet to pass the cable.
5. Pass the cable into the seal nut and seal assembly, then insert the cable into the
unit through the cable gland.
6. Connect the cable cores to the WAGO connector referring to the interconnection
diagram.
20 20
Armor
Inner sheath
Pass the heat shrinkable tube (local supply)
onto the drain wire.
Vinyl tape
Attach the crimp-on lug FV1.25-4(LF)
to the core.
150
150
Drain wire
Drain wire
6
6
Terminal opener
Terminal opener
2. WIRING
2-13