2. WIRING
3. Unplug the WAGO connector (TB1) from the transducer port shown below.
4. Unfasten the seal nut from TRANSDUCER port, and then remove the seal.
5. Run the cable through the seal nut and the seal in order, and then pass the end
of cable into the transceiver through the claw and super gland.
6. Connect the cores to the WAGO connector plug.
The connector opener is attached on the cover. (See figure at step 3)
How to attach wires to the WAGO connector
Wire
Twist
2-8
Transducer
Seal
Seal nut
Push downward
Procedure
1. Twist cores
2. Insert terminal opener and push.
3. Insert wire into hole.
4. Release terminal opener.
Terminal
5. Pull the wire to confirm that it is secure.
opener
Pin #
WAGO connector
CAUTIO
CAUTION
Connect the cores correctly.
Failure to connect the cores as shown in
the table may cause equipment damage or
affect equipment functions.
Terminal opener
Terminal opener
Claw
Core list
Color
Pin #
1
Brown
2
Red
3
Orange
4
Yellow
WAGO
WAGO
connecter
connecter
Color
Green
Blue
Purple
Gray