3.2 Operational Specifications

Range of outputs:
Function
Linear Oxygen #1
Very low Oxygen #1
Linear Oxygen #2
Very low Oxygen #2
Average Oxygen
Logarithmic Oxygen
Reducing Oxygen
Oxygen Deficiency
Auxiliary TC Temperature
Combustibles
Carbon dioxide
Probe #1 Sensor EMF
Probe #2 Sensor EMF
Burner Efficiency
No output
Range of local indication:
Local display, lower line secondary display items:
Function
Probe #1 temperature
Probe #2 temperature
Probe #1 EMF
Probe #2 EMF
Probe #1 sensor impedance
Probe #2 sensor impedance
Oxygen probe #2
Average oxygen, probe #1 and probe #2
Aux temperature
Ambient temperature
Ambient RH
Carbon dioxide
Combustibles
Oxygen deficiency
Burner efficiency
The oxygen deficiency output can be used in the same way as a combustibles analyser to signal the extent
of reducing conditions of combustion processes.
Technical Manual
14
Minimum
0 to 99%
0 to 19,990ppm
0 to 99%
0 to 19,990ppm
0 to 99%
0.1 to 20%
-30
0 to 1x10
%
-10 to 0%
0 to 100°C
0 to 19,000ppm
0 to 5%
0 to 100mV
0 to 100mV
0 to 20.0%
Disables the output
-30
1.0 x 10
to 100%
0.01 to 10,000ppm, automatically defaults to % range above 10,000ppm (1%)
Range
Up to 1760°C (3200°F)
Up to 1760°C (3200°F)
-30 to 1350mV
-30 to 1350mV
0 to 300k Ω
0 to 300k Ω
-30
1x10
-30
1x10
Up to 1760°C (3200°F)
-20° to 70°C (-5° to 125°F)
5 to 95%
0 to 2.0%
0 to 20,000ppm
-10.0 to 20.0%
0 to 100.0%
Maximum
1 to 100%
10 to 20,000ppm
1 to 100%
10 to 20,000ppm
1 to 100%
Fixed range – refer to appendices
0 to 100%
-10 to 20%
0 to 1600°C
0 to 20,000ppm
0 to 100%
0 to 1500mV
0 to 1500mV
0 to 100.0%
to 100%
to 100%