5.6
Peak/Smooth Push Button
Peak/Smooth functions are accessed with this push button. Control is veri-
fied with a short beep. Peak and Smooth functions may be used for volt-
age and current measurements. In THD functions and Hz measurement
mode, only Smooth is active. The PEAK and SMOOTH are reached by
sequentially pressing the push button.
Smooth and Peak are selected by sequentially pressing the Peak/Smooth
push button.
Push Button Sequencing:
In A or V: A or V → Smooth → Peak → A or V
In THD:
In Hz:
5.6.1 Smooth
Smooth stabilizes the digital readings
when measurements are fluctuating. In
this mode, the Model 721 calculates and
displays a three-second average reading.
Smooth may be used in Volts, Amps, Fre-
quency, as well as power quality functions
(%THD, %DF, CF). Smooth may also be
used while in the MIN/MAX recording
mode.
The analog bargraph will not be affected
by the Smooth functions and continues to
display Arms or Vrms.
Harmonic Meter Model 721
THD function → Smooth → THD Function
Hz → Smooth Hz
���������
����
��������������
� � � � � � � � � � �
������
�
�
�
�
�
�
�
���
�
���
�
���
�
35