5.2.1 Ranging
Auto Ranging is selected by default and selects the best range for the
digital display and for the analog bargraph.
Pushing the RANGE push button will select a fixed manual range: 60 Arms
first and 600 Vrms on the second push.
The digital display and the bargraph indicate the selected range. RANGE
is displayed at the top of the display indicating a manual range selection.
Selection is also confirmed with audible tone.
To sequence back to Auto Ranging, push and hold the RANGE push
button for approximately 3 seconds. The displayed RANGE indicator will
disappear, confirmed with an audible tone.
5.2.2 Other Functions
All others push-button functions relating to voltage may be accessed in V:
• THD (%THD, %DF, CF)
• HZ
• PEAK/SMOOTH
• MIN/MAX recording
These functions are described further in this manual (see p. 29-36).
5.2.3 Bargraph
Please note that the analog bargraph will continue to display RMS volt-
age values while other measurement functions are displayed (e.g. %THD,
%DF, CF, Hz, Min/Max, Smooth, Peak). The bargraph ranges are 60 Vrms
and 600 Vrms.
28
Harmonic Meter Model 721