2.2 CONTROL PANEL

CONTROL FUNCTIONS
AC Circuit Breakers
  While the generator is running, the breakers should be in the ON
position.
  If the current has exceeded its limits the breaker will automatically pop
out to the OFF position. Reduce the electrical load on the generator and
push the button back to the ON position.
Low Oil Indicator Light
  The oil alert system is designed to prevent engine damage caused by
an insufficient amount of oil in the crankcase. Before the oil level in the
crankcase reaches an unsafe limit, the oil alert system will automatically
shut down the engine (the power switch remains in the ON position).
  If the oil alert system shuts down the engine, the low oil indicator light
(red) will turn on. Check the engine oil level.
Digital Multi-Display (HG8750, HG10,000)
  Digital display shows the voltage, frequency, session run time, and total
run time. Perform maintenance at the proper intervals according to the
'Maintenance Schedule' section of this manual using the total life run
time.
Battery Charging Port (HG8750, HG10,000)
  When the generator will be stored for an extended period of time plug
the battery charger into a 120V outlet every two months to top up the
battery and prolong its life.
Voltage Selector (HG4050)
  When the switch is set to 240V, the generator will produce both 120 and
240 volt output but only half the power will be available for any 120 volt
receptacle. Full power is available from the 240 volt receptacle in this
position.
  When the voltage selector is set to 120V, full power is available from any
120 volt receptacle.
  Always leave the switch in the 120V position when you don't require 240
volts. Select the voltage before turning on the generator.