Removal Of 12400 Case And Torque Tube S - GE Masoneilan 12420 Instruction Manual & Safety Manual

Masoneilan 12400 series. level transmitter/controller
Table of Contents

Advertisement

9.3. REMOVAL OF 12400 CASE AND TORQUE TUBE SUB-ASSEMBLY (SEE FIGURES 22 & 23)
CAUTION: To remove the displacer, the torque arm must be removed. When the two arm srews (133) are loosened,
hold the torque arm so as not to damage the torque tube (Figure 22).
a.
Switch off power supply.
b.
For instruments with a displacer chamber, close isolation valves, and purge the chamber.
c.
Remove the upper flange (146) and blind flange (144).
d.
Lower the torque arm (135) and unhook the displacer (130). A hook-shaped 3 mm steel wire facilitates unhooking and
holding of the displacer. The wire may be inserted through the clevis hole.
e.
Remove the two torque arm screws (133) and remove the torque arm (135) from the chamber.
f.
Remove the displacer from its chamber (131) or tank.
g.
Be sure that requirements for instruments installed in explosive areas are strictly followed. Remove screw (106) from
connection compartment and unscrew cover (104). Disconnect supply electrical wires and other equipment from
terminals (90).
h.
Remove nuts (142) holding the torque tube subassembly and slide the subassembly out of the mechanism chamber.
Figure 22
130
131
132
133
134
135
137
142
50 | GE Oil & Gas
Displacer
Displacer chamber
Knife of torque tube
Torque arm screw
Torque arm screw block
Torque arm
Torque tube housing S/A
Stud nut
PART REFERENCE
143
Gasket
144
Blind flange
145
Stud
146
Upper flange
147
Upper flange stud
148
Upper flange stud nut
149
Upper flange gasket
Figure 23
® 2014 General Electric Company. All rights reserved.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Masoneilan 12410Masoneilan 12430