Ventilation Product User Manual - Interlinked Operation With Direct Expansion Ventilation; Ventilation Product User Manual - Single Operation With Direct Expansion Ventilation - LG PREMTB001 Owners And Installation Manual

New wide wired remote controller
Hide thumbs Also See for PREMTB001:
Table of Contents

Advertisement

OWNER'S INSTRUCTION
44
Ventilation Product User Manual – Interlinked Operation with
Direct Expansion Ventilation
It can be used only when the air conditioner and the direct expansion ventilator are interlocked.
1
Press
button on the remote controller.
It can be used only when the air conditioner and the ventilator are interlocked.
2
Press
button in the Vent mode to run the ventilator.
P
Press
button in the Vent mode to change the vent mode.
- Each time you press the button the mode will change in the order of Heat exchange ¡ normal ¡ auto.
C It only displays on the remote controller display when it is in ventilation mode, and it displays
the desired temperature when it returns to air condition mode.
N
Press
button in the Vent mode to change the fan speed.
- Each time you press the button the fan speed is selected in the order of low ¡ high ¡ power.
How to convert to air conditioner mode
1) Auto conversion: if no button is selected for more than 15 seconds in the vent mode, the sys-
tem will convert to air conditioner mode automatically.
1
2) Manual conversion: press the
button in the vent mode to convert manually.
Ventilation Product User Manual – Single Operation with Direct
Expansion Ventilation
This function performs ventilation operation with cooling or heating at the same time using the
heat exchanger inside the direct expansion type ventilation product.
2
Press
button on the remote controller.
- The direct expansion ventilator individual operation will be dis-
played as shown in the figure.
P
Press
button in the Vent mode to change the ventilation mode.
- Each time you press the button the mode will change in the order of Heat exchange ¡ normal ¡ auto.
Remote controller
Vent mode
display window
Heat exchange
Circulating the air in the room without any heat loss
Circulating the air in the room without using an electric
Normal
heating exchanger
Circulating the air in the room by comparing the indoor/out-
Auto
door temperatures automatically
In the case of heat exchange mode is shown below.
C The indicator of 88Seg is displayed when only the direct expansion ventilation is operating with
air conditioner OFF.
P
Press
button to convert the operation mode.
- Each time you press the button the mode will change in the order of cooling ¡ heating ¡ auto ¡ stop.
N
Press
button to change the fan speed.
- Each time you press the button the fan speed is selected in the order of low ¡ high ¡ power.
C In the Direct expansion ventilator individual operation, it is possible to select cooling or heating and
to adjust the desired temperature as well.
C See the Standard Operation – Temperature Setting for more information about the desired tempera-
ture adjustment.
OWNER'S INSTRUCTION
45
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premtbb01

Table of Contents