Description

SITRANS F US ultrasonic flowmeters measure flow in standard volumetric units.
Measurement is independent of changes in liquid temperature, density, pressure and
conductivity. A time of flight flowmeter is designed for use on single phase liquids.
They are designed for measurement of:
● Volume flow rate
● Limit monitoring
● Total volume
● Sound velocity in the media
3.1

System components

Table 3- 1
System components, SONO 3100 with FUS060
Sensor
SONO 3100
DN 100 - DN 1200 (40" -
480")
3.2

Design

SITRANS F US SONO 3100 with FUS060 is designed for measuring the flow velocity of
liquids in full pipes. Satisfactory function of the ultrasonic flowmeter depends on a low sound
attenuation of the process media and a well-defined and stable flow profile.
The sensor SONO 3100 with transmitter FUS060 remote mounted measures with a high
accuracy (better than ±0.5% of reading over a wide measuring range).
The sensor is equipped with four transducers of the type SONO 3200.
SITRANS F US SONO 3100
Operating Instructions, 03/2011, A5E00814513-06
Transmitter
FUS060
Outputs
FUS060 with HART:
Analog with HART
Frequency / pulse
Relay
FUS060 with Profibus PA:
Profibus PA
Frequency / pulse
Measurement
Volume flowrate
Total volume
Mass flowrate
Total mass
Sound velocity
Error indication
Limit monitoring
Ultrasonic amplitude
3