Setting the mode switch for single power supply operation:
• if only one power supply is installed (e.g. the C8911 frame has only one PS)
the mode switch "B" must be set to ON in order to turn power fail monitoring off.
Setting the mode switch for C8942 high density frames:
• For the C8942 frames the mode switch "C" must be set to ON to turn sync fail monitoring off
(this frame type has no central sync source) and fan monitoring on.
Setting the mode switch for C8912 dual power supply 19" 1RU frames:
• For the C8912 frames the mode switches "C" and "D" must be set to ON to turn
fan monitoring on.
Reset the C8702:
• press the INIT button briefly at any time and the Frame Controller will reboot immediately.
Important Note! Rebooting the Frame Controller has no effect on audio processing.
Initialize the C8702 to factory default settings:
• Approx. 40 sec. after power is turned on or after pressing the INIT button briefly (reset function),
the STATUS LED lights yellow. Now you may press the INIT button and hold it firmly until the
STATUS LED flashes three times. This is an acknowledgement that the C8702 has been
initialized to factory default settings (you may also hold down the INIT button at any time until the
STATUS LED flashes three times).