digital audio
modular
processing system
Important Note! For high density applications with C8491 or C8492
and C8492(B) compact modules, it is possible to operate the CAN bus
with 1MBit/s to increase the internal bandwidth for loudness logging
and metering. After power-up the C8702 checks the CAN bus and
automaticlly sets its CAN bus speed accordingly. If by accident one
inserts a low speed module afterwards, the C8702 will enter "CAN bus
off mode" and will reboot after a while until that module is removed.
Don't mix up modules which are set to different CAN bus speeds.
For loudenss logging, live plot or bar graph display you must use the J*AM from version 2.9.0 and higher.

Technical specifications

Controller Module
External Connectors
Front panel switch
Front panel LED
Default settings
Power Supply
Dimension
Connector
Environmental
C8000
Frame Controller
Processor
RTC
Operating System
LAN
RS232
CAN
INIT
STATUS
IP address
Net mask
Gateway
Controller CAN ID
Frame address
Can termination
5Vdc (4.75 ... 5.25V), max. 250mA
3RU, 4HP, 160mm depth
DIN41612
Operating temperature
Non-operating
Humidity
Motorola MCF8250 Coldfire
DS1306
eCos
RJ45 10/100Mbit Ethernet
D-Sub 9-pin controller serial interface #1
RJ45 CAN1.1 extension of internal bus
Reset (warm start)
Initialize (factory default)
Yellow = booting / init feedback
Green = operating
10.110.xxx.yyy default calculated from
Ethernet MAC address
255.255.0.0
No entry
0
0
OFF
0 ... 40ºC
-20 ... 70ºC
< 90%, non-condensing
C8702
status display
if 1MBit/s is used: