Tightening Torques; Cable Gland Clamping Range - ABB PVS-100 Product Manual

100 to 120 kw
Hide thumbs Also See for PVS-100:
Table of Contents

Advertisement

T
ightening torques
To maintain the IP66 protection of the system and for optimal installation,
the following tightening torques must be used:

Tightening torques

Single core AC cable gland
Single core PE cable gland
Multi core AC cable gland
Service cable gland
AC connection busbar
AC interface power connector (male)
DC interface connector (male)
Protective earth point (int.)
Protective earth point (ext.)
Junction screws
Side bracket screws
Interface signal connector counterparts
C
able gland clamping range

Cable gland clamping range

Single core AC cable gland
Single core PE cable gland
Multi core AC cable gland
Multi core AC cable gland
Service cable gland
M40
11
M25
11
M63
11
M25
12
bolts
21
24
screws
17
nut
25
nut
10
18
32 34 35
M40
11
M25
11
M63 (type1)
11
M63 (type2)
11
M25
12
- 21 -
2 - Characteristics
5 Nm
5 Nm
18 Nm
5 Nm
25 Nm
3 Nm
screws
3 Nm
21 Nm
12 Nm
12 Nm
5 Nm
0.25 Nm
19...28mm
10...17mm
34...45mm
37...53mm
10...17mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvs-120-tlFimer pvs-100-tlFimer pvs-120-tl

Table of Contents