Characteristics And Technical Data - ABB PVS-100 Product Manual

100 to 120 kw
Hide thumbs Also See for PVS-100:
Table of Contents

Advertisement

C
haracteristics and technical data
Absolute maximum input voltage (Vmax,abs)
Input start-up voltage (Vstart)
Input operating interval (Vdcmin...Vdcmax)
Number of independent MPPT
MPPT DC voltage range (VMPPTmin ... VMPPTmax) to Pacr
Maximum DC input power for each MPPT (Pmppt,max)
Maximum DC input current for each MPPT (Idcmax)
Maximum short circuit current for each MPPT (Iscmax)
Maximum return current (AC side vs DC side)
Number of DC input pairs for each MPPT
Type of input DC connectors
Type of photovoltaic panels that can be connected at
input according to IEC 61730
Input over voltage protection for each MPPT -
Photovoltaic array isolation control
DC switch rating for each MPPT
Fuse rating (versions with fuses)
Nominal AC Output Power (Pacr @cosφ=1)
Maximum AC Output Power (Pacmax @cosφ=1)
Maximum apparent Output power (Smax)
Rated AC Output Voltage (Vacr)
Output voltage range (Vacmin...Vacmin)
Maximum output current (Iacmax)
Contribution to short-circuit current
Rated Output Frequency (fr)
Output Frequency Range (fmin...fmax)
Nominal power factor and setting interval
Total harmonic distortion of current
Maximum AC cable section allowed
Maximum external AC overcurrent protection
Output overvoltage protection -
Maximum Efficiency (ηmax)
Weighted Efficiency (EURO)
Table: Technical Data
Input
Rated input voltage (Vdcr)
Input nominal power(Pdcr)
Input protection
Reverse polarity protection
modular surge arrester
String current monitoring
Output
AC Connection to the grid
AC Connections Type
Output protection
Anti-islanding Protection
Modular surge arresters
Operating performance
PVS-100-TL
1000 V
420 V (400 - 500 V)
360 - 1000V
620 Vdc
102000 W
480 - 850 Vdc
17500 W
[480V≤VMPPT≤850V]
Negligible in normal operating conditions
PV quick fit connector
Class A
Yes, from current limited source
Type II with monitoring only for SX and SX2 versions;
Type I+II with monitoring only for SY and SY2 versions
as per IEC62109
50 A / 1000 V
15 A (gPV/1000 Vdc)
SX2, SY2: Individual string current monitoring (24ch);
SX, SY: Input current monitoring per MPPT (6ch)
Three phase 3W+PE or 4W+PE
100 000 W
100 000 W
100 000 VA
400 V
320...480 V
(5)
145 A
155 A
50 Hz / 60 Hz
45...55 Hz / 55...65 Hz
> 0.995, 0...1 inductive/capacitive with maximum Smax
185 mm
copper/aluminum
2
Busbar for lug connections with M10 bolts (provided);
Single core cable gland plate with 5 individual AC cable glands: 4
x M40: Ø 19...28mm, 1 x M25: Ø 10...17mm
Active frequency drift combined with RoCoF techniques
as per IEC 62116
225 A
Type 2 with monitoring
98.4%
98.2%
- 19 -
2 - Characteristics
PVS-120-TL
720 Vdc
123000 W
6
570 - 850 Vdc
20500 W
[570V≤VMPPT≤850V]
36 A
50 A
(1)
4
(2)
(3)
(4)
120 000 W
120 000 W
120 000 VA
480 V
384...576 V
(5)
(6)
<3%
98.9%
98.6%

Hide quick links: