1.2
LED Display Specifications of the RD77GF
This section lists the LED display specifications of the RD77GF.
Simple Motion
LED display
module status
Normal operation
RUN
ERR
RUN
ERR
Operation failure
RUN
ERR
RUN
ERR
RUN
ERR ●
RUN
ERR
: OFF, : ON, ●: Flashing
*1 When all axes are stopped or on standby, the AX LED turns OFF.
*2 When any of the axes is in operation, the AX LED turns ON.
*3 When an error occurs in any of the axes, the AX LED is flashing.
*4 The AX LED does not turn OFF when the axis is in operation or a minor error (related to axis) has occurred.
Status
Indicates the data link status.
Indicates the data sending/receiving
status.
Indicates the receive data and line error
status.
Indicates the port status.
Indicates the link status.
: OFF, : ON, ●: Flashing
*1 The LED is always OFF in offline mode.
Description
*1
AX1-4
The axes stopped
The axes on standby
*1
AX1-8
*1
AX1-16
*1
AX1-32
*2
AX1-4
The axis in operation
*2
AX1-8
*2
AX1-16
*2
AX1-32
*3
AX1-4 ●
Minor error (related to axis)
*3
AX1-8 ●
*3
AX1-16 ●
*3
AX1-32 ●
*4
AX1-4
Minor error (general)
*4
AX1-8
*4
AX1-16
*4
AX1-32
AX1-4
Flashing (500 ms interval): A data link faulty station detected
Flashing (200 ms interval): Moderate error
AX1-8
AX1-16
AX1-32
AX1-4
Major error
AX1-8
AX1-16
AX1-32
LED display
Description
*1
D LINK
Data link (cyclic transmission being performed)
*1
D LINK ●
Data link (cyclic transmission stopped)
*1
D LINK
Data link not performed (disconnection)
SD/RD
Data being sent or received
SD/RD
Data not sent nor received
L ERR
Abnormal data received
L ERR
Normal data received
L ER
Abnormal data received
L ER
Normal data received
LINK
Link-up
LINK
Link-down
1 PART NAMES
1.2 LED Display Specifications of the RD77GF
1
21