Fronius Symo 3.0-3-S Operating Instructions Manual page 19

Grid-connected inverter
Hide thumbs Also See for Symo 3.0-3-S:
Table of Contents

Advertisement

No. Function
(2)
WLAN LED
-
Flashing green: Fronius Datamanager 2.0 is in Service mode
(IP switch on the Fronius Datamanager 2.0 plug-in card is in position A or Ser-
vice mode has been activated via the inverter display, the WLAN access point
is open)
-
Lights up green: WLAN connection established
-
Flashing green/red (alternately): WLAN access point has timed out following
activation (1 hour)
-
Lights up red: no WLAN connection
-
Flashing red: faulty WLAN connection
-
Does not light up: Fronius Datamanager 2.0 is in Slave mode
(3)
Solar.web connection LED
-
Lights up green: Fronius Solar.web connection established
-
Lights up red: Fronius Solar.web connection is required but has not been es-
tablished
-
Does not light up: no connection to Fronius Solar.web is required
(4)
Supply LED
-
Lights up green: Fronius Solar Net is providing an adequate power supply; Fro-
nius Datamanager 2.0 is ready for use.
-
Does not light up: insufficient or no power supply from Fronius Solar Net - an
external power supply is required
or
the Fronius Datamanager 2.0 is in Slave mode
-
Flashing red: update in progress
IMPORTANT! Never interrupt the power supply while an update is in progress.
-
Lights up red: update failed
(5)
Connection LED
-
Lights up green: connection established within Fronius Solar Net
-
Lights up red: connection within Fronius Solar Net interrupted
-
Does not light up: Fronius Datamanager 2.0 is in Slave mode
(6)
LAN connection
Ethernet interface, colour-coded blue, for connecting the Ethernet cable
(7)
I/Os
Digital inputs and outputs
Modbus RTU 2-wire (RS485):
D-
Modbus data -
D+
Modbus data +
I
IO
RS485
19