Logging interval
Activate / deactivate the logging function and specify a logging interval
Unit
Setting range
Factory setting
30 min.
20 min.
15 min.
10 min.
5 min.
No log
IMPORTANT! In order for the logging function to work correctly the time must be set cor-
rectly.

Relays

Activate relay, relay settings, relay test
Setting range
* these are only shown if the 'E-Manager' function has been activated under 'Relay mode'.
Relay mode
for selecting the different functions of the floating switch contact in the data communica-
tion area:
-
-
-
Setting range
Factory setting
Minutes
30 min. / 20 min./ 15 min./ 10 min./ 5 min./ No log
30 min.
The logging interval is 30 minutes; every 30 minutes new log-
ging data will be saved on the USB stick.
The logging interval is 5 minutes; every 5 minutes new logging
data will be saved on the USB stick.
No data is saved
Relay mode / Relay test / Switch-on point* / Switch-off point*
Alarm function
Active output
Energy Manager
ALL / Permanent / OFF / ON / E-Manager
ALL
Alarm function:
Permanent /
Switch the floating switch contact for permanent and temporary ser-
ALL:
vice codes (e.g. brief interruption to energy being fed into the grid, a
service code occurs a certain number of times a day - can be adjusted
in the 'BASIC' menu)
Active output:
ON:
The floating NO contact is on all the time the inverter is in operation
(as long as the display is not dark or is displaying something).
OFF:
The floating NO contact is off.
Energy Manager:
E-Manager:
Further details on the 'Energy Manager' function may be found in the
"Energy Manager" section.