System Setup; Reference To Opc Ua Specification - Siemens SINUMERIK 840Dsl Configuration Manual

Sinumerik integrate for engineering access mymachine / opc ua
Hide thumbs Also See for SINUMERIK 840Dsl:
Table of Contents

Advertisement

1.3

System setup

Accessibility of the server
The accessibility of the server varies in the particular SINUMERIK systems. The following table
shows the dependencies of the SINUMERIK systems:
SINUMERIK
Accessibility
systems
SINUMERIK
After successful licensing and activation the OPC UA server is accessible via the X130 interface.
828D
SINUMERIK
The OPC UA server needs SINUMERIK Operate and runs on the same place as SINUMERIK Operate. For
840D sl
this reason, system setup depends on whether a Thin Client is used (SINUMERIK Operate runs on NCU)
or a PCU / IPC with Windows operating system. If a Windows operating system is used, the OPC UA server
is also accessible as LocalHost.
Thin Client
PCU / IPC
Application scenario
Figure 1-1
Application scenario
1.4

Reference to OPC UA specification

The SINUMERIK OPC UA server matches the specification of the OPC foundation
opcfoundation.org/) V1.0.3.
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0
If a Thin Client is used, the OPC UA server is accessible after successful licensing
and activation via X130 interface of the NCU.
If a PCU / IPC is used, the OPC UA server is accessible after successful licensing
and activation via "eth1" (X1) interface of the PCU / IPC. In this case the OPC UA
server is not accessible via the X130 interface of the NCU.
1.4 Reference to OPC UA specification
Introduction
(https://
9