Functionality; Overview; Address Space Model - Siemens SINUMERIK 840Dsl Configuration Manual

Sinumerik integrate for engineering access mymachine / opc ua
Hide thumbs Also See for SINUMERIK 840Dsl:
Table of Contents

Advertisement

Functionality

5.1

Overview

Overview
The SINUMERIK OPC UA server provides the possibility to communicate with SINUMERIK
via OPC UA. The following functionalities of the OPC UA specification are supported by the
server:
● Data Access:
● Alarms & Conditions: Event based provision of SINUMERIK alarms and messages from
HMI, NC and PLC
● Methods:
This chapter describes the address space of the SINUMERIK OPC UA server and gives further
information how to address some SINUMERIK specific values. Especially since a lot of
SINUMERIK values are stored in arrays or matrices.
Furthermore the SINUMERIK alarm object is explained and it is shown how to get the alarms
from the server.
At the end of this chapter it is explained how users can transfer files from or to the server using
two comfortable methods.
5.2

Address space model

Address space model
If the OPC UA server is browsed, the available address space is mapped under the "Sinumerik"
node.
Global User Data (GUD) can be found under the "/Sinumerik/GUD" node.
The PLC blocks (inputs, outputs, bit memory, data blocks) can be found under the "/Sinumerik/
Plc" node.
Machine data can be found under the node "/Sinumerik/TEA".
Setting data can be found under the node "/Sinumerik/SEA".
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0
Read, write and subscribe to SINUMERIK variables (NC, PLC)
Transfer of part programs
5
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents