/Random@<NCUName><NodeId> Examples of variable paths (1:N constellation)
Examples of variable paths (1:N constellation)
Variable path
/Random@NCU_1/Channel/Parameter/R[u1,10]
/Random@NCU_2/Channel/Parameter/R[u1,10]
/Random@NCU_1/Plc/DB123.DBB0
Note
The NCU names are listed in the "MMC.ini" file.
Entry:
[GLOBAL]
NcddeMachineNames=NCU1,NCU2
Figure 5-3
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0
NCU names with 1:N
Functionality
5.3 Variable access
Description
R parameter 10 in channel 1 of
NCU_1R parameter 10 in channel
1 of NCU_2
Byte at byte offset 0 in data block
123 of NCU_1