The upstream interfaces and port channels will be configured as follows:
S4048-ON Leaf 3
interface port-channel50
description "Spine 1 and 2"
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 50
interface fo 1/49
description "Spine 1"
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
interface fo 1/50
description "Spine 2"
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
Next, we will create the VLANs. There will be one VLAN for each Isilon subnet; this will also include the
servers in each rack.
S4048-ON Leaf 3
interface vlan200
no shutdown
untagged port-channel 1,3,5,101,102
tagged port-channel 50
Uplink Failure Detection (UFD) is configured next. UFD shuts down all downstream interfaces if all uplinks
fail.
56
Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 4
interface port-channel50
description "Spine 1 and 2"
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 50
interface fo 1/49
description "Spine 1"
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
interface fo 1/50
description "Spine 2"
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
S4048-ON Leaf 4
interface vlan200
no shutdown
untagged port-channel 1,3,5,101,102
tagged port-channel 50