S4048-ON Leaf 1
interface port-channel1
description "Isilon Node 1"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 1
spanning-tree port type edge
interface port-channel3
description "Isilon Node 2"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 3
spanning-tree port type edge
interface port-channel5
description "Isilon Node 3"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 5
spanning-tree port type edge
interface port-channel101
description "Server 1"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 101
spanning-tree port type edge
interface port-channel102
description "Server 2"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 102
spanning-tree port type edge
The downstream interfaces will be configured in the next section. Dell recommends asymmetrical flow control
(rx on tx off) on S4048-ON leaf switches which have sufficient egress buffers to reduce packet drops and
resulting retransmissions. This feature should be applied on all host interfaces that support flow control. In
OS10EE this is enabled by default, in OS9 it must be configured. Flow control commands are added below
for reference; however, they are not required in OS10EE.
48
Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 2
interface port-channel1
description "Isilon Node 1"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 1
spanning-tree port type edge
interface port-channel3
description "Isilon Node 2"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 3
spanning-tree port type edge
interface port-channel5
description "Isilon Node 3"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 5
spanning-tree port type edge
interface port-channel101
description "Server 1"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 101
spanning-tree port type edge
interface port-channel102
description "Server 2"
no shutdown
switchport access vlan 100
mtu 9216
vlt-port-channel 102
spanning-tree port type edge