PM42 Service Repair Manual

Media Hanger and Edge Guides

OPERATION:
This section covers the replacement of ribbon take-up mechanism. Make note of the guide pins when removing the
mechanism on the electronics side.
Tools Required
Description
Torx Driver T20
Allen Driver, 1.5mm-2.0mm
Parts Required
Item Part Number
1
2
3
Ribbon Take-up Replacement
1. Remove the torx screws securing the ribbon rewind assembly module.
2. Remove the Allen set screw to remove the ribbon hub.
3. Remove the C-clips and slide the ribbon rewind assembly toward the electronics side.
4. Reverse the procedure for re-installation.
Ribbon Rewind Assembly Module
Model
L3-GLBL-RPR-3872
PM42
(Rev A)
Description
3
Figure 1
1
DOCUMENT NO.
Page 33 of 48
Spring Plate, 1 Inch Core
PAGE
Qty
1
Location of
Allen set
screw
Figure 2
2