TITLE
PM42 Service Repair Manual
Drive Belt Replacement
1. Remove the motor as per the motor replacement instructions
2. Remove the center ribbon drive gear by removing the mounting screw, see Figure 6
3. Slip the center gear off and lift each drive belt off, see Figures 7 and 8, note relative P/Ns of drive belts as shown in
Figure 8 , lower belt P/N 655-321-001(189mm) and upper ribbon take up drive is P/N 655-323-001 (162mm)
4. For installation reverse these steps
Figure 6
Roller Tension Replacement
1. Remove the motor as per the motor replacement instructions.
2. Remove the 3 mounting screws as shown in red circles. See Figure7.
3. Lift and remove the Roller Tension assembly as shown in Figure 9, loosen the belt tension screw for this step.
Model
DOCUMENT NO.
L3-GLBL-RPR-3872
PM42
(Rev A)
Figure 4
Figure 7
Figure 9
PAGE
Page 42 of 48
Figure 5
Figure 8
Pulley, Drive Kit, Spare