No.
U051
Wiper control can be prohibited
: Wiper output prohibited
: Wiper output enabled
Thread breakage detection selection
U071
: Prohibited
U072
Number of invalid stitches at the start of sewing of
thread breakage detection
U073
Number of invalid stitches during sewing of thread
breakage detection
U074
The fan operation can be set
: Energy saving mode
: Constantly operates
U075
With/without air pressure detection
: Without
U105
Intermediate presser : wiper sweeping position
: Upper wiping
* Displayed only for the LK-1920
U129
With/without needle cooler control
: Without
U132
Selection of the tension controller No. 3 mode
: Inversion shaft
: Tension controller No. 3
U133
Selection of the return-to-origin route for the inversion pattern
: Reverse trace prohibited
: Reverse trace enabled
U134
With/without disc floating device control
: Without
Function
: Enabled
: With
: Lower wiping
: With
: With
Setting range
-
-
0 to 15
0 to 15
-
-
-
-
-
-
-
53
State when
Remarks
delivered
8
3
For the LK-1910A
and LK-1920A, the air
presser detection can
be set to
When the inversion pat-
tern is used, the inver-
sion-specific operation
is prohibited by means
of the inversion output.
.