Bridge Card Redundancy - Studer OnAir 3000 Service Instructions Manual

Digital mixing system
Hide thumbs Also See for OnAir 3000:
Table of Contents

Advertisement

SCore Live
2.2.1

Bridge Card Redundancy

Single Bridge Card
8 SCore Live
Since Vista SW V4.1, a redundant Bridge card can be used in the SCoreLive.
This provides not only cable redundancy but also true bridge card redundancy.
The order no. of the bridge card with this functionality is A943.0370.35 or
later; earlier bridge cards cannot be upgraded to this level.
Note
When using a redundant bridge card, the SCoreLive's maximum capacity for
DSP cards is reduced from 9 to 8 cards.
VISTA 9
PC 1
LAN 1
IP: 192.168.1.128
IP: 192.168.3.128
SUBN: 255.255.255.0
LAN 2
IP: 192.168.2.128
IP: 192.168.4.128
SUBN: 255.255.255.0
Switch 1
SCore Live
BRIDGE 1
IP Port 1
192.168.1.60
IP Port 2
192.168.2.60
SUBN:
255.255.255.0
In the example above, the single bridge card must be installed in slot 10 of
the SCoreLive frame; the maximum number of DSP cards is 9.
PC 2
LAN 1
IP: 192.168.1.129
IP: 192.168.4.129
SUBN: 255.255.255.0
LAN 2
IP: 192.168.2.129
IP: 192.168.3.129
SUBN: 255.255.255.0
Switch 2
Date printed: 28.02.11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents