Part 5 Troubleshooting; Metaza Doesn't Run When Marking Data Is Sent; Dr. Metaza Does Not Function - Roland Metaza MPX-50 User Manual

Metal printer
Table of Contents

Advertisement

5
5
Part

Metaza doesn't run when marking data is sent.

What to check
Is the power for METAZA
switched on?
Is the cable connected?
Is the correct type of cable used?
Is the driver set to the correct port?
Is the STANDBY LED flashing?
The Dr.METAZA does not function.
What to check
Does the computer provide the
correct system requirements for
Dr. METAZA?
Was the software installed using
the setup program?
Troubleshooting
Press the [STANDBY] key to switch on the power.
Check whether the printer cable is loose or detached.
If the cable is loose or detached, switch off the power and reconnect the cable.
The type of parallel cable (printer cable) may vary according to the computer
model. Make the connection with the correct type of cable for the computer.
Make sure the driver is set to the port where the printer cable is connected. If the
computer has only one port, select [LPT1] for the port setting.
The STANDBY LED flashes when some error occurs in Metaza.
Stop sending data and switch off the power to Metaza. Eliminate the cause of the
error, then send the marking data again.
Use a computer that matches the system requirements for Dr. METAZA. For more
information about the system requirements for Dr. METAZA, see "Installing the
Software."
Be sure to use the setup program when installing Dr. METAZA.
The setup program puts the files in the necessary locations to enable the software
to be used under Windows.

Part 5 Troubleshooting

Remedy
Remedy
45

Advertisement

Table of Contents
loading

Table of Contents