Installation & User's Manual

2. Power Requirements

WARNING! The PLPROFILE4 MKII LED Luminaire should be connected to a constant circuit or a relay device. It
should never be connected to a dimmer or circuit controlled by a dimmer.
The PLPROFILE4 MKII LED Luminaire operates on 100 to 240 volts AC (+/- 10%,
auto-ranging). The luminaire contains an auto-ranging power supply. Depending on
supply voltage, each luminaire can draw up to 580 Watts. The maximum through
current should not exceed 20 Amps*.
WARNING! *Maximum Allowable Input Current of 20 Amps (maximum power supply limit of 580 Watts). Do not
overload circuits! Must be supplied by a branch circuit protected by a maximum 20 Amp circuit protector. Doit
être alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit protecteur. Do not
overload circuits!
IMPORTANT AC POWER CONNECTION NOTES:
a. Must be supplied by a branch circuit protected by a
maximum 20 Amp circuit protector. Doit être alimenté par
un circuit de dérivation protégé par un maximum de 20
ampères circuit protecteur.
b. When using the daisy-chain connection method, ONLY
connect PLPROFILE4 MKII LED Luminaires to AC Output
Connection of PLPROFILE4 MKII LED Luminaires. DO
NOT CONNECT OTHER TYPES OF LUMINAIRES OR
DEVICES!
c. Use only approved cable types.
d. Do not overload circuits!
e. Do not connect PLPROFILE4 MKII LED Luminaires to
dimmed circuits.
f. The MAXIMUM allowable number of PLPROFILE4 MKII
LED Luminaires which can be 'daisy-chained' on one power
feed should not exceed ratings. DO NOT EXCEED!
8
INSTALLATION AND SET UP
PLPROFILE4 MKII LED Luminaires
AC Input Only!