Installation & Operation Guide
CONNECTING POWER
The LightPack LED Module is supplied with an AC input cable. Some versions are sold with
AC input connectors installed.
WARNING: DO NOT power module from a dimmed source. Connect to standard
power or mechanical relay ONLY.
To AC Power
CONNECTING DATA
DMX512 Connections
The LightPack LED Module supports standard USITT DMX512/1990 protocol. A termination
plug (Strand # 71346) is required at the last module in the data link.
DMX512 In Cable
LED Luminaire Port Connections
The LightPack LED Module
supports the control of two LED
luminaires through its two LED
Luminaire ports.
WARNING:
The LightPack
LED Module is only for use with
certain LED luminaires. See
"SPECIFICATIONS" on page 9
for more information.
6
AC Input Wiring - 120V Models
Wire Color
Description
Black
White
Green
Figure 4: AC Power
DMX512 Out/Thru Cable
or Termination Plug
Figure 5: DMX512 Connections
1
2
Figure 6: LED Luminaire Connections
AC Input Wiring - 230V Models
Line
Neutral
Green/Yellow
Ground
Connectioning.com
DMX 5-Pin Connectors Pinout:
Pin
1
2
3
4
5
LED Module 4-Pin Connector Pinout:
Pin
4
3
LightPack LED Module
Wire Color
Description
Brown
Blue
Neutral
Ground
Signal
Common (Drain)
DMX512 -
DMX512 +
No Connection
No Connection
Signal
1
+24 Volts DC
2
Not Used
3
Data
4
Ground
Line