HES K20 (13.56 MHz RFID) stand-alone cabinet lock

Package contents

Public Mode (One -time Use)
Lock the door
a
b
Flashes
3 times
a
Close the cabinet door and present a
User Credential
-3x flashing Red LED's followed by a
long beep
Rotate the knob to the locked position
b
Set Up for Public & Private Mode
Step 1
Touch
for 3 secs
Flashing
for 3 secs
a
Present "1st" Master Credential for 3 seconds
to set programming mode
-Followed by a short beep
※ -Note: Only the "1st" Master Credential can be
used to set programming mode
Instruction Manual
One (1) HES K20 cabinet lock
1
One (1) Rubber washer
2
One (1) M6 nut
3
One (1) Flat and one (1) Offset Locking Cam
4
Two (2) M4 washers
5
Five (5) Pan Head Phillips Screws
6
M4 x10mm locking cam screw
6-1
M4 x10mm (1-5mm thick door)
6-2
M4 x 20 mm (10-15mm thick door)
M4 x 25 mm (15-20mm thick door)
M4 x 30 mm (20-25mm thick door)
Power : 4.5V
(AAA 1.5V x 3)
Unlock the door
a
b
Flashes
3 times
a
Present a registered User Credential
-3x flashing Yellow LED's followed by an
extended beep
b
Rotate the knob to the locked position and
open the cabinet door
※ Public Mode (One time use)
- Previously registered User Credential will be
erased after unlock and remain open for next user.
Step 2
Public mode
Private mode
b-1
b-2
Flash
Flash
1 time
3 times
b
Public Mode
2x flashing Amber LED's followed by a short beep
Private Mode
3x flashing Amber LED's followed by a long beep

Hardware Installation

1

User Credentials in Private Mode

문을 열때
Unlock the door
a
Flashes
3 times
a
Present a registered User Credentia
-3x flashing Yellow LED's followed by an
extended beep
Rotate the knob to the unlocked position
b
and open the cabinet door

Emergency Power

Step 1
a
b
Flashes
5 times
a
Connect a standard 5 pin Micro USB cable to
the USB port on the right side of the lock
b
When power is applied, both LED's flash 5x
followed by an extended beep
5-5/64" (129 mm)
6-2
5
-Risk of explosion if battery is replaced
by an incorrect type.
-Please only use new alkaline batteries.
5
4
3
2
문을 잠글 때
Lock the door
b
Flashes
3 times
Close the cabinet door and rotate the knob
a
to the locked position
-3x flashing Red LED's followed by a long beep
※ Private Mode (Ongoing use)
- Return the handle to the locked position.
The lock will automatically relock after 3 seconds.
Step 2
c
b
OR
USER
c
Present a valid User Credential or Master Credential
to unlock the cabinet
-Existing user credentials will be deleted when a valid
Master Credential is used.
-User Credentials will need to be set again during
programming of private mode.
d
Open the door and change all 3 batteries
Caution

LED Feedback

-Red
-Yellow
-Amber
6-1

Audio Feedback

Short Beep - "Beep-"
Std. Beep - "Sol-Do~"
Long Beep - "Do-Mi-Sol~"
a
d
MASTER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HES K20 and is the answer not in the manual?

Questions and answers

Summary of Contents for Assa Abloy HES K20

  • Page 1 Instruction Manual HES K20 (13.56 MHz RFID) stand-alone cabinet lock Package contents Hardware Installation One (1) HES K20 cabinet lock Caution One (1) Rubber washer One (1) M6 nut -Risk of explosion if battery is replaced One (1) Flat and one (1) Offset Locking Cam by an incorrect type.
  • Page 2 Registering Credentials Step 1 : Master Credentials Step 2 : Override Credentials Step 3 : User Credentials Flashing for 8 secs Flashing Flashes for 8 secs 3 times Flashing for 8 secs Private Mode Public Mode End of Master Credential programming mode Present a credential to register as a Master Credential starts Override Credential programming mode - Note: The first credential presented will be registered...

Table of Contents