2 Channel Mode (RECEIVE 2C)
Channel
DMX value
range
1
0-12
Low-fog
13- 240
output
level
241 -255
2
0-50
Control
51-100
functions
101-150
151-200
201-255
To activate a control function, the DMX value must be held in the
correct range for 5 seconds.
S e t t i n g o p t i o n s b y R D M
You can remotely configure the fixture over DMX using RDM. Martin offers a
range of suitable RDM-compatible controllers.
A full list of the RDM functions that the machine supports is given at the end of
this section. These functions are generally referred to using the more specific
term 'PIDs' or 'Parameter IDs'.
Scanning for RDM devices on the data link
Before you can communicate with fixtures using RDM, you must send a scan
command (also called a device discovery command) to all the devices on the
data link so that the RDM controller can identify them. It does this by retrieving
each device's factory-set unique identifier (UID). This process can take some
time depending on the number of devices on the link.
To identify the fixtures on the link:
1.
Check that the fixtures are correctly connected to the RDM controller on
the data link and that power is applied to all fixtures.
2.
Give the controller time to identify the devices on the link and prepare
for communication with the devices.
Getting status and setting options by RDM
The status and options listed in the table below can be read and set by RDM.
Function
Macro description
Idle range
None
Output 0-
100%
Output 100%
No function
Prime
Primes the machine
No function
OFF-
Switches off heating
Shutdown
and cooling,
engages the
shutdown procedure
Standby -
Switches on the
Heaters on
heating and cooling
systems, machine in
Standby
DMX control
Default
value
0