Installation and setting up

DANGER! DO NOT operate the machine until you have read and observed all
the precautions listed under "Safety information" on page 4.
L o c a t i o n
The machine is designed to be operated in a dry location on the floor and should
be kept in horizontal orientation. The maximum deviation from horizontal is 2°.
Ensure the machine has at least 60 cm (24 in.) clearance all-round and at least
60cm (24 inches) away from combustible and heat-sensitive materials. Ensure
the same distance from the fog output if ducted.
A C p o w e r
Before using the machine, ensure that a grounding-type (earthed) power plug
that matches the local power receptacle is installed on the power cable
provided.
This machine has a high earth leakage current and must only be operated from
supplies with ground fault detection set at 30 mA. Only use an industrial
receptacle/plug combination that reliably ensures earth connectivity before line
connection. For example plugs and sockets conforming to any of the following:-
IEC 60309-1
IEC 60309-2
UL 1682/1686
CSA C22.2
For operating from supplies in the range 208 to 250 V, a minimum rated
supply capacity of 20 A is required.
When installing the plug to the machine's mains cable, follow the plug
manufacturer's instructions and connect pins as follows:
Yellow and green wire to ground (earth), blue wire to neutral and brown wire to
live.
The table below shows some common pin identification schemes.
wire
brown
blue
green/yellow
function
marking
live
"L"
neutral
"N"
earth
Installation and setting up
screw colour
yellow or brass
silver
green
10