Vitosol 100-FM/200-FM Installation, Operating and Service
Installing the Mounting Frames
Installation dimensions for Vitosol-FM, Model SV collector panels
Dimensions for model SV collectors
Number of collectors
Dimension A
inches
(mm)
Dimension B
inches
(mm)
Dimension C
inches
(mm)
Dimension D*1
inches
(mm)
Dimension E
inches
(mm)
Dimension F
inches
(mm)
Dimension G
inches
(mm)
Dimension H
inches
(mm)
*1 For static reasons, maintain the stated sequence. Maintain the dimensions A and B as far as possible. Roof
brackets may also be offset if you need to locate roof joist. However, always maintain the overall dimension.
(continued)
1
2
40
40
(1019)
(1019)
(1019)
--
--
42b
(1077)
1b
2c
(39.5)
(68.5)
40
80a
122b
(1019)
(2038)
(3115)
A
A+A
A+B+A
43a
85b
128c
(1098)
(2175)
(3273)
3b
3b
(87.5)
(87.5)
36a
36a
36a
(923)
(923)
(923)
--
6
(154)
(154)
3
4
40
40
40
(1019)
(1019)
42b
42b
(1077)
(1077)
3
3
3b
(79)
(79)
(89.5)
165
207b
(4192)
(5269)
A + 2xB+ A
A + 3xB+ A
171a
214b
(4350)
(5448)
4
4
4a
(98)
(98)
(108.5)
36a
36a
(923)
(923)
6
6
(154)
(154)
Installation on Sloped Roofs
5
6
8
40
40
(1019)
(1019)
42b
42b
(1077)
(1077)
4
3b
(100)
(89.5)
249c
334b
(6346)
(8500)
A +4xB+ A
A +6xB+ A
256c
342b
(6525)
(8700)
4a
4c
(108.5)
(119)
36a
36a
(923)
(923)
6
6
6
(154)
(154)
10
40
(1019)
42b
(1077)
4b
(110.5)
419b
(10654)
A +8xB+ A
428
(10875)
5
(129.5)
36a
(923)
6
(154)
9