Viessmann Vitosol 100-FM SV1F Installation, Operating And Service Instructions page 23

Flat plate solar collectors for sloped roofs, flat roofs, walls and freestanding installation
Table of Contents

Advertisement

Vitosol 100-FM/200-FM Installation, Operating and Service
Installing Freestanding Installation
Legend
A Collector connection
B Spacer lip of the support brace qQ
C Rating plate
D Interconnection pipe qE
Note: See page 16 for numbered component description.
(with ballast - for Model SH only)
8.
Position the first collector into the retaining bracket
9 and push right up to the spacer lip of the
connecting brace. Center the distance when fitting
only a single collector.
IMPORTANT
Install the collector panel so that the rating plate C
side of the first and last collector is on the outside (note
sticker)! If only one collector is to be installed, connect
the piping opposite the rating plate C side. See page 30
for more information.
9.
Before inserting interconnection pipe D, mark the
middle of the connecting pipe with a marker or a
piece of tape for reference. Insert the interconnection
pipe D into the collector until the brass section is no
longer visible.
IMPORTANT
Interconnection pipes must be free from damage and
contamination. Lubricate all plug-in joints (O-ring seals) on
the collectors. Use only the special grease supplied with
the connection set.
10. Carefully push the next collector up to the collector
that was just installed. Insert the supply and return
interconnection pipes D (top and bottom) into the
collector headers. Carefully push the collector up
to the spacer lip B of the support brace qQ. Visually
inspect the interconnection pipes D to ensure that
they are centered between the two collectors.
IMPORTANT
Ensure interconnection pipe is centered between
collectors.
11. Click clamping brackets qP into the collector edge at
the top of all supports.
12. Secure the support brace qQ to the next collector
support 1 using the clamping brackets qP between
the second and third, the fourth and fifth supports, etc.
13. The distance between collectors should be no greater
than the width of the spacer lip B on the support
brace which is 1a" (32.8 mm).
14. Tighten all bolts.
Installation on Flat Roofs
or Freestanding Installation
(continued)
23