Type sp3a vacuum tube collector based on the heat pipe principle (32 pages)
Summary of Contents for Viessmann VITOSOL 100-F
Page 1
VIESMANN VITOSOL 100-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist VITOSOL 100-F Type SV1 and SH1 Flat-plate collectors for installation on end or across, for installation on flat and pitched roofs and for freestand- ing installation.
Up to 10 collectors can be linked in par- & Easy to assemble Viessmann fixing system with load tested and allel. corrosion-resistant components made from stainless steel and aluminium – standard for all Viessmann collectors.
In a cold, sealed system, the collectors must be pressurised to at least 1.0 bar. The idle temperature is the temperature that occurs at the hottest part of the collector when no heat is drawn off (at 1000 W global radiation). VIESMANN VITOSOL 100-F...
Specification (cont.) Type SH1 KR Collector return (inlet) KV Collector flow (outlet) Delivered condition The Vitosol 100-F is delivered fully assembled and fully wired. Accessories Packed separately, subject to order: & Connection lines, 1.0 m long, 2 pce. & The fixing set with product documentation contains the compo- &...